All of the electrodes listed below should be stored dry at room temp when in unopened cartons.
Electrode Classification | Recommended
Storage open Boxes | Holding
Oven | Reconditioning |
E-XX10 |
Dry
@ room temp | Not
Recommended | Not
done |
E-XX11 |
Dry
@ room temp | Not
Recommended | Not
done |
E-XX12 |
Dry
@ room temp | Not
Recommended | Not
done |
E-XX13 |
Dry
@ room temp | Not
Recommended | Not
done |
E-XX14 |
150
- 200 F | 150
- 200 F | 250
- 300 F 1 hr. |
E-XX20 |
150
- 200 F | 150
- 200 F | 250
- 300 F 1 hr. |
E-XX24 |
150
- 200 F | 150
- 200 F | 250
- 300 F 1 hr. |
E-XX27 |
150
- 200 F | 150
- 200 F | 250
- 300 F 1 hr. |
E-60 or 7015 | 250
- 450 F | 150
- 200 F | 500
- 600 F 1 hr. |
E-60 or 7016 | 250
- 450 F | 150
- 200 F | 500
- 600 F 1 hr. |
E-7018 |
250
- 450 F | 150
- 200 F | 500
- 600 F 1 hr. |
E-7028 |
250
- 450 F | 150
- 200 F | 500
- 600 F 1 hr. |
E-80 or 9015 | 250
- 450 F | 200
- 250 F | 600
- 700 F 1 hr. |
E-80 or 9016 | 250
- 450 F | 200
- 250 F | 600
- 700 F 1 hr. |
E-80 or 9018 | 250
- 450 F | 200
- 250 F | 600
- 700 F 1 hr. |
E-90 12015 | 250
- 450 F | 200
- 250 F | 650
- 750 F 1 hr. |
E-90 12016 | 250
- 450 F | 200
- 250 F | 650
- 750 F 1 hr. |
E-90 12018 | 250
- 450 F | 200
- 250 F | 650
- 750 F 1 hr. |
E -XXX-15 or 16 | 250
- 450 F | 150
- 200 F | 450
F 1 hr. |
Stainless |
250
- 450 F | 150
- 200 F | 450
F 1 hr. |
When being reconditioned, electrodes should not be baked for more than 4 hours and should be kept at temp for at least 30 minutes. Baking more than 3 times is not recommended. |