All
of the electrodes listed below should be stored dry at room temp when in unopened
cartons.
Electrode Classification |
Recommended
Storage open Boxes |
Holding
Oven |
Reconditioning
|
E-XX10 |
Dry
@ room temp |
Not
Recommended |
Not
done |
E-XX11 |
Dry
@ room temp |
Not
Recommended |
Not
done |
E-XX12 |
Dry
@ room temp |
Not
Recommended |
Not
done |
E-XX13 |
Dry
@ room temp |
Not
Recommended |
Not
done |
E-XX14 |
150
– 200 F |
150
– 200 F |
250
– 300 F 1 hr. |
E-XX20 |
150
– 200 F |
150
– 200 F |
250
– 300 F 1 hr. |
E-XX24 |
150
– 200 F |
150
– 200 F |
250
– 300 F 1 hr. |
E-XX27 |
150
– 200 F |
150
– 200 F |
250
– 300 F 1 hr. |
E-60 or 7015 |
250
– 450 F |
150
– 200 F |
500
– 600 F 1 hr. |
E-60 or 7016 |
250
– 450 F |
150
– 200 F |
500
– 600 F 1 hr. |
E-7018 |
250
– 450 F |
150
– 200 F |
500
– 600 F 1 hr. |
E-7028 |
250
– 450 F |
150
– 200 F |
500
– 600 F 1 hr. |
E-80 or 9015 |
250
– 450 F |
200
– 250 F |
600
– 700 F 1 hr. |
E-80 or 9016 |
250
– 450 F |
200
– 250 F |
600
– 700 F 1 hr. |
E-80 or 9018 |
250
– 450 F |
200
– 250 F |
600
– 700 F 1 hr. |
E-90 12015 |
250
– 450 F |
200
– 250 F |
650
– 750 F 1 hr. |
E-90 12016 |
250
– 450 F |
200
– 250 F |
650
– 750 F 1 hr. |
E-90 12018 |
250
– 450 F |
200
– 250 F |
650
– 750 F 1 hr. |
E -XXX-15 or 16 |
250
– 450 F |
150
– 200 F |
450
F 1 hr. |
Stainless |
250
– 450 F |
150
– 200 F |
450
F 1 hr. |
When being reconditioned, electrodes should not be baked for more than 4 hours and should be kept at temp for at least 30 minutes. Baking more than 3 times is not recommended. |